Installation of Submersible pump
Author:CHANGLONG From:本站原创 Browse:894 Time:2002-01-01 18:40:33
Penetrating the three lines of submersible pump into the walking line tube, install the piston and the O- shape airproof loop in one pipe end,

1.Covering the walking line tube into the oil lead tube and then spin in the pump swivel, the same as the oil lead tube and the walking line tube to turn on into the pump head, pay attention to the piston of the walking line tube to spread the butter;

2.Joining the motor of submersible pump and the oil lead together, pay attention the localization of the lead wire needle is in the right place;

3.Connecting the power line and capacitance : the white streak connects with white strea, the red streak connects with the capacitive plug; after connecting the black streak and the black streak then connecting the plug;

4.Connecting the breather pipe and the pump 1/4" screw, fixed with the tube card;

5.Jointing the supporting tube and the connection flange (user supplies for oneself), fixes in the oil tank mouth;

6.After the normal working electrifying of assembled submersible pump, covering the supporting tube, then tighting the oil tank;

7.In order to eliminate "the impingement effect" in the pipeline, suggested installs a section of metal tube in the pump oil mouth; Adjusts the pump position, with dispenser’s pipe line docking (also available seamless steel pipe direct docking);

8.Connecting 220V power.

9.Installation is finished.
Explanation:
1.Before install the submersible pump, the user should supply the specification of using oil tank to the supplier, in order to the system non-periodical corresponding oil lead, walking line tube and the breath
Tube size;
2.The distance between the central line of motor inside submersible pump and the central line of the oil pot oiling tube shouldn’t smaller than 1m, if it is , it is possibly to stagnate the area after transferring the oil, causing no oil putting of submersible pump.

3.The altitude of oil tank in-putting hole, specific should be supplied by user: